Unlike its predecessor, the EO Mini Pro 2 has a dedicated 30mA Type A RCD on the supply circuit. It also has an integrated 6mA DC leakage detection circuit. However, it lacks an "O-PEN" protection feature, which would detect a faulty earth connection into the property and shut down the charger. This is important because a defective charger could cause the car body to become live.